JOSLYN,
MSP® SURGE PROTECTOR
2027-SERIES, 2-POLE GAS TUBE
UL RECOGNIZED
|
Model Numbering
|
2027-09
|
2027-15
|
2027-23
|
2027-25
|
2027-35
|
|
DC Sparkover, 100 V/s
|
90 V
|
150 V
|
230 V
|
250 V
|
350 V
|
|
(72-108)
|
(120-180)
|
(184-276)
|
(200-300)
|
(280-420)
|
|
|
Impulse Sparkover, 100 V/µs
|
350 V
|
400 V
|
525 V
|
550 V
|
650 V
|
|
1 kV/µs
|
600 V
|
550 V
|
675 V
|
700 V
|
800 V
|
| Insulation Resistance | 100 V (50 V for -09) | >1010ohm |
| Glow Voltage | 10 mA | 70 V |
| Arc Voltage | 10 V | |
| Glow-Arc Transition Current | <.5 A | |
| Capacitance | 1 MHz | <1 pF |
| DC Holdover Voltage | 135 V (52V for -09, 80V for -15) | <150 ms |
| Impulse Discharge Current | 25 kA 8/20 µs † | 1 Operation |
| 5 kA 8/20 µs (10kA for -09 and -15) | 10 Operations | |
| 500 A 10/1000 µs | 500 Operations | |
| 100 A 10/1000 µs | 1000 Operations | |
| Alternating Discharge Current | 65 Arms, 11 cycles (9 cycles at 50 Hz) † | 1 Operation |
| 10 Arms, 1 s | 10 Operations | |
| Operating Temperature | - 55 to 250 C | |
| Warranty | 1 Year | |
| CHARACTERISTICS Test methods per ITU-T K.12 |

| UL File E153537. Electrodes are nickel plated | Available without preionizing material: add’Y’ to the model |
| Lead wires are tin plated copper | number (i.e., 2027-23-AY). Disregard first dc sparkover value. |
| Model number marking on tube: 27-xxxV | After discharge: sparkover limits increase by 10 %, measured |
| Ceramic is treated with AntiTrac moisture proofing | 24 hours after discharge, resistance > 108ohm |
| BT1 tape sequencing per EIA RS-296-D, 1000 pcs/spool | †Tube will remain functional without shorting or venting |